Andrew Beck

My feedback

  1. 28 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck commented  · 

    Having this option would make designs in industrial areas much cleaner. Right now we are designing equipment to homerun either (1) from the equipment itself or (2) from a junction box that feeds other equipment with the same conductor size. In reality, we'd be using a junction box with multiple wire sizes in the homerun, so our current designs are misleading.

    Andrew Beck supported this idea  · 
  2. 7 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck commented  · 

    To add to this: we'd like a separate circuit callout and homerun callout layer. Since the looping options apply to all device types, we are unable to show homerun + circuit callouts for receptacles while only showing homeruns for lighting. Having separate layers for homerun and circuit callouts would address this.

  3. 3 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck shared this idea  · 
  4. 151 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck commented  · 

    I know "branch wires" are mentioned in the wish description, but it would also be nice if feeder wires were upsized based on voltage drop.

  5. 26 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck supported this idea  · 
  6. 240 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck supported this idea  · 
  7. 10 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck shared this idea  · 
  8. 31 votes
    Vote
    Sign in
    (thinking…)
    Sign in with: Facebook Google
    Signed in as (Sign out)
    You have left! (?) (thinking…)
    Andrew Beck commented  · 

    DesignMaster currently loops devices using arcs. We'd like an option to change looping from using arcs to use polylines (we differentiate between MC cable and conduits with arcs and polylines, respectively). Ideally these polylines would offset themselves similar to how feeder polylines are offset during one-line generation.

Feedback and Knowledge Base